Pcb Assembly Services Expanding engineering support for turnkey PCBA Published 2026-11-25 11:00:00 “This board arced between two unconnected output terminals under 15V DC, and in severe cases, it caught fire directly.”This comment from the client marked the start of the whole incident. A batch of PCBAs suffered successive arcing failures during field operation, with individual boards catching fire. For any electronic product, this is a top-tier quality incident. Below is a full review of this failure analysis, detailing our troubleshooting, root cause identification and recurrence prevention measures.1. Failure Phenomenon: Not an Isolated Incident, But a Batch IssueThe client did not report sporadic failures. Instead, a batch of boards exhibited arcing between two normally unconnected output terminals at 15V DC, and some boards caught fire under severe conditions.No electrical connection was designed between these two terminals, meaning no current path should exist under normal operation. Arcing indicates insulation breakdown between the terminals and the formation of an unintended discharge path.2. Step 1: Review Design MarginUpon receiving the feedback, we first cross-checked design documents to answer one core question: What voltage rating was this clearance designed for?The review showed the gap between the two output terminals was originally specified for a higher voltage class. Theoretically, breakdown should not occur at 15V. In other words, the root cause did not lie in the rated capability of the design. This raised the critical question: why did breakdown occur in practical use?3. Step 2: Check Changes and Pinpoint DifferencesWhen product failures occur, the fastest investigation route is always to trace where changes were introduced.Item-by-item verification revealed the only modification for this batch was in an area of the Gerber file unrelated to this function. This zone was electrically isolated via optocouplers and had no electrical linkage to the two arcing terminals.Conclusion from change review: the modification itself was not the direct trigger. Still, this investigation delivered a key lesson: all changes, even those deemed irrelevant, should be placed at the top of the failure analysis checklist, as field anomalies from clients are often strongly correlated with change windows.4. Step 3: Review Batch Records and Operating EnvironmentAfter ruling out design flaws and engineering changes, we moved to two further investigation directions:Batch consistency: Process parameters, material lots and storage conditions of this batch were compared against other production lots one by one; no abnormal deviations on the manufacturing side were confirmed.Operating environment: Arcing is highly relevant to creepage distance. Ambient temperature, humidity and contamination at the client site can drastically shift the breakdown threshold of insulating media. The same clearance carries entirely different safety margins between dry, clean conditions and high-humidity, contaminated environments.This is where the value of failure analysis lies. It does not assume conclusions in advance. Instead, it opens up four dimensions — design, changes, manufacturing process and environment — for sequential elimination and evidence collection. Our FA findings are strictly based on test records and collected evidence, with no vague speculation.5. Review Takeaways and Recurrence Prevention MechanismsThree formalized mechanisms were established from this case:Upgraded change control: All Gerber / design revisions, whether or not they affect electrical functions, must go through the Engineering Change Notice (ECN) review workflow. Creepage and insulation clearance shall be rechecked before and after each change.Voltage gap verification: Terminal clearances for seemingly low-voltage applications from clients shall be reviewed against the harshest environmental conditions, rather than only referencing the nominal voltage.Failure analysis archive: Each FA case is documented with failure symptoms, investigation workflow, evidence records and corrective actions, serving as design input for future projects.We shared the full analysis workflow and conclusions with the client openly and transparently. What clients truly value is not a zero-failure track record, but whether the manufacturer can deliver a responsible response within days once a failure emerges.PCBA failure analysis does not rely on luck. It relies on a robust system: traceable changes, verified clearances, and fully considered operating environments. Many “unexpected” failures can be avoided if these three points are well managed.If you are facing similar failure issues with your products, feel free to send us the boards and failure descriptions. We will conduct a complete FA following the “design – change – process – environment” framework and deliver a traceable investigation report.